1-877-238-8357 order line, 1-985-748-5163 technical assistance |
|
Greenhouses and Greenhouse Kits in Alphabetical Order Acadian Greenhouse™ Bayou Greenhouse™ Evangeline Greenhouse™
Accessories for Greenhouses in Alphabetical Order
Miscellaneous Pages
Gifts for Gardeners
Greenhouses are perfect for over wintering plants
|
Greenhouse Environmental Controls Note: All electric products must be installed in accordance with local codes All items this page include shipping to continental US
Timers, Photo Controller, Cooling Thermostat, Humidity Controllers, CO2 Controllers, Multi Function Controllers (Control multiple functions: Lights, CO2, Irrigation, Humidity, Temperature), Power Modules Eco Plus 24 Hour Programmable Timer Dual Timer with Large display. Easy to use. This timer has tabs which are equivalent to 15 minutes. You simply push in the tabs when you want your equipment running. Rated for 15 amps. Programmable at 15 minute intervals.
Eco Plus Digital Plug in Timer Dual timer with easy to use large display. Rated for 15 amps.
24 Hour and 7 Day Electronic Plug - in Timer
Features 12 programs (6 on; 6 off) / programming: 1
minute intervals. Built-in battery for reserve carry-over. Easy to program.
Manual switch. Grounded 3-conductor plug and receptacle.
7 Day Programmable Heavy Duty Grounded Digital Timer Controls all types of loads, such
as lamps (including fluorescent), providing up
to 14 ON / 14 OFF settings per day or 98 ON / 98 Off settings in a week. It
plugs directly into wall outlet (3-prong grounded plug and receptacle).
Easy-to-set hand-held programming , LCD digital clock and readout with
“to-the-minute“ setting for accuracy. Features a manual override. For programming information click here
Encore Repeat Cycle Timer Perfect for indoor gardens, greenhouses, foggers, misters, sprayers, pumps, fans and any other application requiring automatic short cycle on and off timing. Choose cycle running times between 5 seconds and 30 minutes with interval gaps ranging between 5 minutes and 8 hours. Easy to read, control and set up. Plugs directly into standard power outlet with 78" power cord. Connects to timed equipment via 13" cord. Operates on 120 volts A.C. with 15 amp switching capacity. To view a programming guide, click here
Cyclestat 4P Repeat Cycle Timer The Cyclestat 4P is perfect for plant zone environments, reptile habitats or any other application requiring automatic short cycle switching. No programming required. Easy to set and operate. Microprocessor time counter with adjustable frequency and duration. The Cyclestat 4P timer has many uses. Only a few of them include: fogging or misting, spray stakes or drip system timing, air pumps, CO2 equipment and intake or exhaust fan control. The Cyclestat may be set for interval and cycle of timed events. Interval is the time between “ON” cycles. The interval knob may be set from 5 minutes to 8 hours. Set this for desired time between functions. Cycle is the length of time that a specific function or condition must be maintained. Cycle may be set from 5 seconds to 30 minutes.
Chronometric Sequential Timer The CST-1 has solved the age old problem of accurate short cycle timing. The only unit of it’s kind designed specifically for the control of grow systems. Easy to set and operate. Solid state time counter with adjustable frequency and duration. The CST-1 function timer has many uses and only a few of them include: fogging or misting, spray stakes or drip system timing, air pumps, CO2 equipment and intake exhaust fan control.
Day Night
Photo Switch
The PS-1 Photostat is used to turn equipment “Off” during a photo “Off” period (night operation). When the lights are “Off” the control equipment will be powered down. In this mode the Photostat is ideal for use in CO2 generation. The Photostat may also be used to turn equipment “Off” during a photo “On” period (Daylight Operation). Switch between day or night operation. The PS-1 can also be used to operate indoor or supplementary lighting to correspond to natural outdoor daylight hours as seasons change. In DAY mode locate the PS-1 so it detects outdoor day length and functions your indoor lighting timer accordingly.
24 Hour Timer/ Cooling Thermostat This unit operates equipment up to 15 amps @ 120 volts. Housed in a corrosive - resistant black anodized chassis, this controller offers a synchronous, motor driven time switch with 96 daily 15 minute increments and a built in adjustable, independent thermostat. Plug timed equipment into the left side of the controller and plug temperature controlled equipment into the right side. The durable solid state offers a 7 degree differential (comfort zone). Optional 3 degree external coil or remote bulb thermostats are available.
Tempstat Thermostat The Temp H/C Temperature Controller is switchable between heat and cool. Perfect for plant zone environments, reptile habitats or any other application requiring automatic switching of heating and cooling equipment. The black anodized aluminum enclosure is durable and attractive and will never corrode or discolor from hot, cold or humid environments. Available with 3º or 7º differential span or 7º Remote Bulb Thermostat. This control operates AC, exhaust fans, evaporative coolers, heaters or other temperature equipment by activating switches, motors, valves or pumps. Temperature range 40º to 110º F (5º to 45º C).
Total Humidity Controller - Humidify and Dehumidify
Control humidity automatically and accurately with
the Total Humidity Controller.
Relative Humidity Controller - Humidify or Dehumidify The RHC Relative Humidity Controller is our most recent development in total humidity control. It is switchable between humidify and dehumidify. The RHC has a built-in on board sensor which is accurate within +/- 5% with a set differential of 5%, and temperature compensation. Perfect for plant zone environments, reptile habitats, or just about any application requiring accurate response and control. The 702370 is identical in function to 702365 but offers a 20 foot remote sensor. Both units operate equipment up to 15 amps @ 120 volts.
Environmental Controllers CO2 These systems are a breakthrough in
CO2 detection and control. The CDMC-6 system is designed to sample the air
and learn the characteristic of your space, then make adjustments as
necessary to ensure a constant level of CO2. The CDM-6000 monitor employs a
passive infrared sensor which samples the air once every second and then
sends the sample data to the CDDS-2 sequencer. The CDDS-2 then activates or
deactivates your CO2 enrichment or venting (exhaust) equipment to maintain
desired CO2 PPM. The CDDS-2 uses a sophisticated adaptive algorithm or
“Overshoot Protection Logic” to learn the dynamics of the space being
controlled. This allows the systems to avoid dramatic overshoots inherent to
set point controllers or timed CO2 enrichment. These learned parameters are
stored in the memory, even when the ‘POWER’ is off, or until you reset the
unit. The CDMC-6 system offers a large LCD screen displaying the current CO2
levels in PPM. Set your desired CO2 level, ‘Hysteresis’ and ‘Elevation’ to
maintain precise levels without guesswork. The CDMC-6 system can be using
for enriching or venting CO2 and incorporates a photo sensor to defeat
CDDS - 2 and CDM - 7001 Sensor The CDMC-7 system functions like the CDMC-6 for CO2 enrichment or ventilation, but offers the added features of a portable monitor in the CDM-7001 with dual beam absorption infrared technology and a LCD display that shows CO2 PPM and real time temperature. The CDM-7001 monitor is also equipped with a computer interface to download CO2 history. Recorded data can be graphed and printed using a Windows based VG graphing software (not included).
Integrated Cooling Thermostat and Dehumidistat/ 4 outlets This CT-DH-1 is designed to turn “On” and “Off” exhaust fans and/or intake fans to remove unwanted atmosphere due to heat or humidity. This device is intended as a cooling and dehumidifying control. This controller is ideal for situations where excess heat and humidity need to be exhausted. Internal sensors will allow a 7° temperature comfort zone and a 7% humidity span (differential) between the time the fans go “Off” and come back “On” again. When either temperature or humidity exceeds the dial settings, all four outlets will turn “ON”, activating any cooling or exhaust equipment plugged into the controller.
Independent Cooling and Heating Thermostat / 4 outlets This controller features fully independent sensors for cooling and heating equipment. The cooling thermostat activates the left outlets of the controller and the heating thermostat activates the right outlets. If you require a tighter control of your temperature than the internal heating \ cooling thermostats allow, alternate sensors are available with a 3º differential (External Coil). * Also available with a 7º Remote Bulb Thermostat.
Synchronized Cooling Thermostat / Dehumidistat While the CT-DH-3 has many applications, it was primarily developed to be used with CO2 equipment and exhaust type fans. Internal sensors will allow a 7° temperature comfort zone and a 7% humidity (differential) between the time the fans go “Off “and come back “On” again. Temperature or humidity raise will activate the right hand outlets and deactivate the left hand outlets. The CT-DH-3 has an internal relay that automatically switches power from the left side (CO2 Outlets) to the right side (Exhaust Outlets) of the unit when either temperature, humidity or both are in excess of the dial settings. Plug the controller into a power surge protector to protect your valuable equipment, and then plug the surge protector into a 110 wall outlet. Set the temperature and humidity to the desired settings. The left side of the controller is normally in the “ON” position and is able to activate CO2 equipment as needed. The CT-DH-4P is designed to be used with CO2 equipment, dehumidifiers, and exhaust fans. While it is similar to the CT-DH-3 it has the added feature of offering independent outlets for temperature and humidity control. It is ideally suited for use with dehumidifiers. Temperature raise will activate the right hand outlets and deactivate the CO2 outlet. Humidity rise will activate the dehumidifying outlet. Internal sensors will allow a 7° temperature comfort zone and a 7% humidity (differential) between the time the equipment goes “Off “and comes back “On” again. Plug the controller into a power surge protector to protect your valuable equipment, and then plug the surge protector into a 110 wall outlet. Set the temperature and humidity to the desired settings. The CO2 outlet is normally in the “On” position and is able to activate CO2 equipment as needed, but is defeated when exhaust function is active. The photo sensor will defeat CO2 enrichment during darkness hours. * SYNCHRONIZED COOLING
THERMOSTAT /DEHUMIDISTAT / 4 OUTLETS Model CT-DH-3
Microclimate Controller System / 8 Outlet
The Micro Climate Controller MCC-1 is designed to
perform all the major atmospheric * Operates on 110VAC with 15 Amp switching capacity.
24 HR. Timestat Controllers Model TSC-1 The TSC-1 timer is a 24 hr. time switch that provides accurate timing with 96 non detachable trippers for On/Off functions adjustable in 15 Min. increments up to 48 cycles per day. Easy to set and operate. Constructed with durable, black anodized, aluminum housings that will never corrode or discolor for hot, cold or humid environments. This unit can be used independently or as part of a combination of control devices to coordinate numerous system functions. Precision synchronous clock motor provides 15 amp 110V control for pumps, fans, lighting, solenoids, motors, relays or virtually any equipment or appliance dependent upon multiple daily operations.
High Amperage Relay Model HAR-1 This power relay uses high amperage
capacity contacts to transfer power to large
4 Light Timer - 120 Volts Model LT4-120 These time switches are designed to
operate high load lighting equipment. They consist of a premium quality
precision synchronous clock motor and a high amperage switching circuit.
These controllers are housed in black anodized brush finish aluminum
enclosures
|
|
|